Estimates only — get local quotes before you buy. Read our methodology.
The ratings in one place
| Rating | Applies to | What it measures |
|---|---|---|
| SEER2 | Air conditioners and heat pumps (cooling) | Seasonal cooling output per unit of electricity, tested at higher duct pressure than the old SEER method |
| EER2 | Air conditioners and heat pumps | Efficiency at a single hot condition, which matters in hot, dry climates |
| HSPF2 | Heat pumps (heating) | Seasonal heating output per unit of electricity |
| AFUE | Gas and oil furnaces and boilers | Share of fuel energy that becomes heat |
| UEF | Water heaters | Uniform energy factor, comparable across fuel types |
Higher is better for all of them. SEER2, EER2 and HSPF2 replaced SEER, EER and HSPF for equipment installed from 2023. The new test method uses more realistic duct pressure, so SEER2 numbers read lower than the old SEER numbers for the same equipment. A rough conversion is that SEER2 is about 4% to 5% lower than SEER.
Current federal minimums
Minimums for split-system air conditioners vary by region. In the northern states the minimum is 13.4 SEER2 for split system ACs, and in the South and Southwest it is 14.3 SEER2. The Southwest also has an EER2 minimum. Heat pumps have a national minimum of 14.3 SEER2 and 7.5 HSPF2 for split systems. Check the current rule and your region, since the details differ by capacity and system type. Furnace minimums are described in our furnace AFUE guide.
ENERGY STAR labels equipment that beats the minimums by a set margin. Meeting ENERGY STAR is not required for any federal incentive now. Federal 25C and 25D credits ended for installations after December 31, 2025. State, local and utility incentives vary and often depend on a minimum SEER2 or HSPF2.
How much does a higher SEER2 save?
Annual cooling cost equals cooling energy delivered divided by SEER2, times your electricity price. The table assumes a 3-ton system (36,000 BTU per hour) running the equivalent of 1,000 full-load hours a year. That is an illustrative assumption. Real full-load hours range from a few hundred in cool northern areas to well over 2,000 in the hottest ones.
| State | Electricity | 13.4 SEER2 | 14.3 SEER2 | 16 SEER2 | 18 SEER2 | 20 SEER2 |
|---|---|---|---|---|---|---|
| California | 31.97 cents/kWh | $859 | $805 | $719 | $639 | $575 |
| New York | 24.43 cents/kWh | $656 | $615 | $550 | $489 | $440 |
| Minnesota | 15.45 cents/kWh | $415 | $389 | $348 | $309 | $278 |
| Texas | 14.94 cents/kWh | $401 | $376 | $336 | $299 | $269 |
| Florida | 14.14 cents/kWh | $380 | $356 | $318 | $283 | $255 |
Going from 14.3 to 18 SEER2 saves about $165 per year in California, $126 in New York, $80 in Minnesota, $77 in Texas and $73 in Florida under these assumptions. In Texas or Florida with more full-load hours, say 2,000, those savings double. They still need to be compared to the price of the upgrade.
Simple payback
Payback in years equals the extra purchase price divided by yearly savings. If a higher-efficiency model adds $1,500 and saves $77 a year, payback is almost 20 years, longer than most equipment lasts. If it adds $1,500 and saves $330 a year in a hot, high-rate market, payback is about 4.5 years. Request two quotes on identical scope, one at the minimum and one at the higher tier, so the premium is real and not guessed.
Lab ratings versus real performance
- Installation quality matters more than a couple of SEER2 points. Wrong refrigerant charge, restricted airflow and leaky ducts can cut performance far more than the efficiency gap between models.
- Matched systems. Ratings apply to the specific indoor and outdoor combination listed with AHRI. A mismatched coil may not deliver the rating.
- Variable-speed equipment earns high SEER2 ratings by running at low speeds, but only with correct sizing and controls.
- Humidity. In humid climates, how well a system removes moisture matters for comfort. Oversized systems with high ratings can still feel clammy.
Sizing is critical. Use the BTU and tonnage calculator as a first check, then ask for a Manual J load calculation.
Installed costs in our data
| Area | AC low | AC typical | AC high | Heat pump typical |
|---|---|---|---|---|
| National median | $3,326 | $5,826 | $11,280 | $10,406 |
| California | $3,625 | $6,343 | $12,846 | $10,778 |
| Texas | $3,362 | $5,828 | $11,314 | $9,406 |
| Florida | $3,375 | $5,775 | $11,015 | $9,333 |
State figures are on the AC replacement cost page and the heat pump installation cost page. Try your own inputs in the AC replacement cost calculator.
Equipment moving from R-410A to R-454B and R-32 refrigerants in 2025 and 2026 may shift prices. Refrigerant work requires EPA Section 608 certified technicians.
Which rating to prioritize
- Hot, humid or cooling-dominated climates: SEER2 and EER2 matter most, plus dehumidification.
- Cold climates with a heat pump: HSPF2 alone is not enough. Look for capacity and efficiency at low temperatures.
- Mild climates with low usage: A minimum-efficiency unit installed well is often the better value.
For the broader decision, see Are heat pumps worth it? and our guide to comparing HVAC quotes.
Estimates only
These numbers are estimates only. Get local quotes before you buy. Method and limits are on the methodology page.
FAQ
What is a good SEER2 rating?
It depends on your region, climate and usage. Federal minimums are 13.4 to 14.3 SEER2 for split systems depending on region. Higher tiers cost more and pay back faster in hot, high-use markets.
Is SEER2 the same as SEER?
No. SEER2 uses a newer test method with higher duct pressure, so the numbers are lower than SEER for the same equipment.
Does a high SEER2 guarantee low bills?
No. Sizing, installation quality, duct condition and your thermostat habits also drive bills.
Is ENERGY STAR worth it?
It signals better-than-minimum efficiency, but you still need to check payback on the price premium.
Sources
- U.S. Department of Energy, Energy Saver, central air conditioning: https://www.energy.gov/energysaver/central-air-conditioning (accessed 2026-11-23)
- U.S. Department of Energy, appliance and equipment standards for central air conditioners and heat pumps: https://www.energy.gov/eere/buildings/appliance-and-equipment-standards-program (accessed 2026-11-23)
- ENERGY STAR, central air conditioners and heat pumps: https://www.energystar.gov/products/heating_cooling (accessed 2026-11-23)
- U.S. Energy Information Administration, residential electricity prices: https://www.eia.gov/electricity/ (accessed 2026-11-23)